EMTP Simulation of VFTO’s for 420 kV GIS


(*) Corresponding author


Authors' affiliations


DOI's assignment:
the author of the article can submit here a request for assignment of a DOI number to this resource!
Cost of the service: euros 10,00 (for a DOI)

Abstract


Very Fast Transient Over voltages(VFTO) are generated due to switching operations and faults in a Gas Insulated Substation(GIS) needs lot of insight to safe guard the equipment and insulation of various systems. VFTOs can also cause malfunction of protection circuits and control circuits. These transients have traveling wave behavior; they travel to the external systems through enclosures, bushings, cable joints etc., and cause damage to the outside equipment. They can lead to secondary break downs in GIS and may give rise to electromagnetic interference. Thus it is important to develop a suitable simulation models for estimation of these over voltages. In order to estimate the over voltages, equivalent electrical network models are developed. This paper focused on 420 kV GIS system and equivalent model of GIS bus duct have been considered for the simulation of VFTOs. GIS equivalent models have been developed for various lengths of bus duct and simulations to estimate VFTOs are carried out with switching operations of Disconnector switch and fault conditions at various locations. The suppression of VFTOs are also simulated by inserting resistance across the disconnector switch. Comparison has been made in terms of voltage magnitudes with and without suppression methods. Significant reduction of voltage magnitudes are observed in this work. For simulation of equivalent GIS models Electro Magnetic Transient Programming (EMTP) is used.
Copyright © 2013 Praise Worthy Prize - All rights reserved.

Keywords


Disconnector Switching; EMTP; GIS; Suppression Methods; Very Fast Transient Over Voltages (VFTO)

Full Text:

PDF


References


Working Group 33/13-09 (1988), “Very Fast Transient Phenomenon Associated with Gas Insulated Substations”, CIGRE.

D. Povh, H. Schmitt, O. Volcker, R. Witzmann, “Modelling and Analysis Guidelines for Very Fast Transients”, IEEE Trans. on PD, Vol. 11, No. 4, October 1996, pp. 2028-2035.

B.P. Singh, G.B.D. Varaprasad, K. Uday Kumar, “EMTP simulation of Fast Transients in Gas Insulated Switchgear”.

Z. Haznadar, S. Carsimamovic, R. Mahmutcehajic, “More Accurate Modelling of Gas Insulated Substation Components in Digital Simulations of Very Fast Electromagnetic Transients”, IEEE Trans. on PD, Vol. 7, No. 1, January 1992, pp. 434-441.

S.A. Boggs, F.Y. Chu, N. Fujimoto, “Disconnect Switch Induced Transients and Trapped Charge in Gas Insulated Substations”, IEEE Trans. on PAS, Vol. PAS-101, No. 10, October 1982, pp. 3593-3601.

Masdi, H., Mariun, N., Transient response study on transformer windings under impulse voltage stresses, (2010) International Review of Electrical Engineering (IREE), 5 (3), pp. 1022-1026.

S. Ogawa, E. Haginomori, S. Nishiwaki, T. Yoshida, K. Terasaka, “Estimation of Re-Striking Transient Over Voltage on Disconnecting Switch for GIS”, IEEE Trans. on PS, Vol.PWRD-1, No. 2, April 1986, pp.95-101.

Rodrigues, R.B., Mendes, V.M.F., Catalão, J.P.S., Electromagnetic transients analysis of lightning overvoltages on wind power plants, (2010) International Review of Electrical Engineering (IREE), 5 (4), pp. 1678-1684.

Amir Mansour Miri and Zlatan Stojkovk, “Transient Electromagnetic Phenomena in the Secondary Circuits of Voltage-and-Current Transformers in GIS (Measurements and Calculations)”, IEEE Trans. on PD, Vol. 16, No. 4, October 2001, pp. 571-575.

Tavakoli, A., Gholami, A., Suppression of fast and very fast transients in gis, (2010) International Review of Electrical Engineering (IREE), 5 (5), pp. 2439-2445.

Nobuhiro Shimoda, Kazuo Taguchi, “Suppression of Very Fast Transients Over Voltages Across Insulating Flange of 1000KV GIS”, High Voltage Engineering Symposium, 22-27 August 1999, Conference Publication No. 467, IEE, 1999, pp. 2.415.P1-2.418.P1.

J. Ozawa, T. Yamagiwa, M. Hosokawa, S. Takeuchi, H. Kozawa, “Suppression of Fast Transient Over Voltage during Gas Disconnector Switching in GIS”, IEEE Trans. on PD, Vol.PWRD-1, No. 4, October 1986, pp. 194-201.


Refbacks

  • There are currently no refbacks.



Please send any question about this web site to info@praiseworthyprize.com
Copyright © 2005-2024 Praise Worthy Prize