Analysis of Humidified Air Circulation Over the Air Cooled Condenser of Vapour Compression Refrigeration System with Eco Friendly Refrigerants


(*) Corresponding author


Authors' affiliations


DOI's assignment:
the author of the article can submit here a request for assignment of a DOI number to this resource!
Cost of the service: euros 10,00 (for a DOI)

Abstract


The performance behavior of vapour compression refrigeration system (VCRS) has been examined in two modes of operation namely atmospheric air circulation (AAC) and humidified air circulation (HAC) over the condensing coil at different loading conditions in the evaporator. This experimental work is carried out by using the refrigerant mixture of R290 and R600a which are eco friendly refrigerants as compared to conventional refrigerants like R12 and R134a. Humidifier unit is assembled with the existing VCRS and the mass flow rate of water supplied is maintained about 1.08 lit/sec. The various performance parameters like coefficient of performance (COP), refrigeration effect, heat rejection in the condenser and power input to the compressor are measured experimentally at different loads in the evaporator. The experimental results of the proposed investigation shows that 19.1% reduction in compressor power consumption and progressive increase in refrigeration effect & COP. COP of HAC mode is about 26.88% higher than AAC mode at 75% loading conditions.
Copyright © 2014 Praise Worthy Prize - All rights reserved.

Keywords


Coefficient of Performance; Power Consumption; Heat Rejection; Humidifier

Full Text:

PDF


References


Thangavel P, Somasundaram P. Part load performance of analysis of vapour compression refrigeration system with hydrocarbons refrigerants. J Sci Ind Res 2013; 72: 454-60.

Hajidavalloo E, Eghtedari H. Performance improvement of air-cooled refrigeration system by using evaporatively cooled air condenser. Int J Refrig 2010; 33:983-88.

Nasr MM, Salah Hassan M. Experimental and theoretical investigation of an innovative evaporative condenser for residential refrigerator. Renewable Energy 2009; 34:2447–54.

Ebrahim Hajidavalloo. Application of evaporative cooling on the condenser of window-air-conditioner. Appl Therm Eng 2007; 27:1937–43.

Camargo JR, Ebinuma CD. A mathematical model for direct evaporative cooling air conditioning system. Engenharia Termica 2003; 4:30-34.

Maheshwari GP, Al-Ragom F, Suri RK. Energy-saving potential of an indirect evaporative cooler. Appl Energy 2001; 69:69-76.

Mertin Ertunc H, Murat Hosoz. Comparative analysis of an evaporative condenser using artificial neural network and adaptive neuro-fuzzy inference system. Int J Refrig 2008; 31:1426-36.

Senthilkumar K, Srinivasan PSS. Experimental study of centrifugal humidifier fitted in an industrial shed located in tropical climates. J Therm Sci 2011; 15:467-75.

Krishan Kant, Ashvini Kumar1 SC. Mullick. Space conditioning using evaporative cooling for summers in Delhi. Build. Environ. 2001; 36:15-25.

Eric Granryd. Hydrocarbons as refrigerants – an overview. Int J Refrig 2001; 24:15-24.

Mohanraj M, Jayaraj S, Muraleedharan C. Comparative assessment of environmental-friendly alternatives to R134a in domestic refrigerators. Int J Energy Effic 2008;1: 189-98.

Ching-Song Jwo, Chen-Ching Tig, Wei-Ru Wang. Efficiency analysis of home refrigerators by replacing hydrocarbon refrigerants. Int J Measurements 2009; 42:697–01.

Yunho Hwang. Reinhard Radermacher, William Kopko. An experimental evaluation of a residential-sized evaporatively cooled condenser. Int J Refrig 2001; 24:238-49.

Mohanraj M, Jayaraj S, Muraleedharan C, Chandrasekar P. Experimental investigation of R290/R600a mixture as an alternative to R134a in a domestic refrigerator. Int J Therm Sci 2009; 48:1036–42.

Fatouh M, El Kafafy M. Experimental evaluation of a domestic refrigerator working with LPG. Appl Therm Eng 2006; 26:1593–03.

Hammad MA, Alsaad MA. The use of hydrocarbon mixtures as refrigerants in domestic refrigerators. Appl Thermal Eng 1999; 19:1181–89.

Jia Yang, Chan KT, Xiangsheng Wu, Xiaofeng Yang, Honagyu Zhang. Performance enhancement of air-cooled chillers with water mist: Experimental and analytical investigation. Appl Thermal Eng 2012; 20:114–20.

Boulet P, Tissot T, Trinquet F, Fournaison. Enhancement of heat exchanges on a condenser using an air flow containing water droplets. Appl Thermal Eng 2013; 50:1164–73.

Arrora C P, Refrigeration and Air conditioning (Tata McGrew-Hill Publishing Company Ltd.) 2004.

Thangavel, P., Somasundaram, P., Navaneethakrishnan, P., Simulation analysis on thermo physical properties of hydrocarbon refrigerants in vapour compression refrigeration system, (2013) International Review of Mechanical Engineering (IREME), 7 (4), pp. 646-651.

Sivakumar, M., Somasundaram, P., Thangavel, P., Exergy and performance analysis of three stage auto Refrigerating Cascade (3 stage ARC) system using Zeotropic mixture of eco-friendly refrigerants, (2014) International Review of Mechanical Engineering (IREME), 8 (1), pp. 124-134.

Patil, S.S., Auti, A.B., Singh, T.P., CFD and experimental analysis of a condenser for domestic desalination system, (2013) International Review of Mechanical Engineering (IREME), 7 (6), pp. 1159-1163.

Chandraprabu, V., Sankaranarayanan, G., Iniyan, S., Suresh, S., Siva, V., Heat transfer enhancement performance of Al2O3/water nanofluid in condensing unit of air conditioner: Experimental study, (2013) International Review of Mechanical Engineering (IREME), 7 (4), pp. 686-691.

Senanayake, N.S., Efficiency improvement of domestic refrigerators by condenser modification, (2012) International Review of Mechanical Engineering (IREME), 6 (6), pp. 1356-1360.


Refbacks