The induced vibrations from the operation of a railway system can cause annoyance to human and possible damage to the load bearing system of a monument. Appropriately designed track specially associated with trains in tunnels is applied in order to eliminate the amplitude of transmitted vibrations. The efficiency of the implementation of certain criteria is examined comparing theoretical model evaluation & numerical experimental tests from an extensive monitoring program carried out during the regular operation of Athens Metro at the vicinity of Kapnikarea church. From the results it is evident that numerical analysis leads to a very reliable prediction of the response of a monument.
Copyright © 2018 Praise Worthy Prize - All rights reserved.

Keywords


Groundborne Noise; Vibration; Environmental Monitoring; Monument Protection; Underground Transportation Systems

Full Text:

PDF


References


Vogiatzis K., Mouzakis Ch., Criteria for vibration from railway & light rail transportation projects construction for the protection of buildings and the avoidance of annoyance, ΕΠΙΣΤΗΜΟΝΙΚΟ ΚΤΙΡΙΟ, Β/1999, pages: 57-59.

Vogiatzis K., Mouzakis Ch., (2002), Noise & Vibration for the evaluation of the possible anti vibration measures for the protection of Kapnikarea church from Athens Metro operation, ET&T Consulting Eng. Ltd. - ATTIKO METRO SA - Final Report April 2002.

Von Gierke H. E., Guidelines for Preparing Environmental Impact Statements on Noise, Committee on Hearing, Bioacoustics, and Biomechanics Assembly for Behavioral and Social Sciences (CHABA), Working Group 69, For: National Research Council, NTIS AD A044384, 1977.

Vogiatzis K., Mouzakis Ch., (2003), Noise & Vibrations monitoring during the initial phase of Athens Metro operation at Kapnikarea’s Church (Testing & Full Operation System) Phase Α’ & Β’ (ET&T Consulting Eng. Ltd. - ATTIKO METRO SA TSA 245) & Submission of the Final Report on a full 15 day monitoring program (ΕΤ&Τ/ΑΜ TSA 255).

Vogiatzis K., Mouzakis Ch., (2009), Noise & Vibrations Monitoring Program For The Protection Of Kapnikarea Church From Athens Metro, Proceedings of MONUBASIN 2010, Patras, Greece.