Open Access Open Access  Restricted Access Subscription or Fee Access

Analysis of the Performance of the Norton Equivalent Model of a Photovoltaic System Under Different Operating Scenarios


(*) Corresponding author


Authors' affiliations


DOI: https://doi.org/10.15866/iree.v16i4.20278

Abstract


The massive integration of photovoltaic systems to distribution networks has affected their operation in terms of harmonic distortion in voltage and current signals. This is due to the non-linear characteristic of photovoltaic inverters. For this reason, it is necessary to characterize these systems in different operating scenarios in order to analyze in detail their impacts on electrical grids. However, only a few studies use frequency domain models in order to study their real behavior. Therefore, this work seeks to estimate the parameters of the Norton equivalent model of the coupled and decoupled admittance matrix of a photovoltaic system that injects active power into the low voltage network of a university building. It is proposed to analyze the performance of the model with three operating scenarios based on solar irradiance, active power generated and the THDi index. Measurements at the common coupling point between the photovoltaic system and the electrical network have been taken into account in order to obtain the models and validate them. The results obtained show the analysis of the performance of the models for the three proposed operating states, in terms of powers, power factor, estimation of the waveforms of the current signal and the THDi index.
Copyright © 2021 Praise Worthy Prize - All rights reserved.

Keywords


Active Power; Harmonic Distortion; Norton Model; PV System; Solar Irradiance

Full Text:

PDF


References


T. Adefarati and R. C. Bansal, Integration of renewable distributed generators into the distribution system: A review, IET Renewable Power Generation, vol. 10, no. 7. pp. 873-884, 2016.
https://doi.org/10.1049/iet-rpg.2015.0378

S. Jain, S. Kalambe, G. Agnihotri, and A. Mishra, Distributed generation deployment: State-of-the-art of distribution system planning in sustainable era, Renew. Sustain. Energy Rev., vol. 77, no. February, pp. 363-385, 2017.
https://doi.org/10.1016/j.rser.2017.04.024

A. Rezaee Jordehi, Allocation of distributed generation units in electric power systems: A review, Renew. Sustain. Energy Rev., vol. 56, pp. 893-905, 2016.
https://doi.org/10.1016/j.rser.2015.11.086

H. Hong, Z. Hu, R. Guo, J. Ma, and J. Tian, Directed graph-based distribution network reconfiguration for operation mode adjustment and service restoration considering distributed generation, J. Mod. Power Syst. Clean Energy, vol. 5, no. 1, pp. 142-149, 2017.
https://doi.org/10.1007/s40565-016-0198-3

M. M. Haque and P. Wolfs, A review of high PV penetrations in LV distribution networks: Present status, impacts and mitigation measures, Renew. Sustain. Energy Rev., vol. 62, pp. 1195-1208, 2016.
https://doi.org/10.1016/j.rser.2016.04.025

T. Matlokotsi and S. Chowdhury, Power quality enhancement in sub-transmission and distribution networks using grid-integrated renewable distributed generation, in 2017 52nd International Universities Power Engineering Conference, UPEC 2017, 2017, vol. 2017-Janua, pp. 1-6.
https://doi.org/10.1109/UPEC.2017.8232011

J. H. De Oliveira, J. P. R. Gomes, W. D. C. Boaventura, and V. F. Mendes, Impact of integrating a photovoltaic power plant in a distribution feeder, Proc. Int. Conf. Harmon. Qual. Power, ICHQP, vol. 2016-Decem, pp. 842-847, 2016.
https://doi.org/10.1109/ICHQP.2016.7783372

A. Medina et al., Harmonic analysis in frequency and time domain, IEEE Trans. Power Deliv., vol. 28, no. 3, pp. 1813-1821, 2013.
https://doi.org/10.1109/TPWRD.2013.2258688

A. S. N. Huda and R. Živanović, Large-scale integration of distributed generation into distribution networks: Study objectives, review of models and computational tools, Renew. Sustain. Energy Rev., vol. 76, no. December 2015, pp. 974-988, 2017.
https://doi.org/10.1016/j.rser.2017.03.069

D. Chathurangi, U. Jayatunga, M. Rathnayake, A. Wickramasinghe, A. Agalgaonkar, and S. Perera, Potential power quality impacts on LV distribution networks with high penetration levels of solar PV, Proc. Int. Conf. Harmon. Qual. Power, ICHQP, vol. 2018-May, pp. 1-6, 2018.
https://doi.org/10.1109/ICHQP.2018.8378890

W. Grycan, B. Brusilowicz, and M. Kupaj, Photovoltaic farm impact on parameters of power quality and the current legislation, Sol. Energy, vol. 165, no. November 2017, pp. 189-198, 2018.
https://doi.org/10.1016/j.solener.2018.03.016

M. Ding, Z. Xu, W. Wang, X. Wang, Y. Song, and D. Chen, A review on China's large-scale PV integration: Progress, challenges and recommendations, Renew. Sustain. Energy Rev., vol. 53, pp. 639-652, 2016.
https://doi.org/10.1016/j.rser.2015.09.009

M. Kaspirek, L. Mikulas, and D. Mezera, Analysis of voltage quality parameters in LV distribution grids with connected distributed energy sources, CIRED - Open Access Proc. J., vol. 2017, no. 1, pp. 513-516, 2017.
https://doi.org/10.1049/oap-cired.2017.0111

A. Elkholy, Harmonics assessment and mathematical modeling of power quality parameters for low voltage grid connected photovoltaic systems, Sol. Energy, vol. 183, no. March, pp. 315-326, 2019.
https://doi.org/10.1016/j.solener.2019.03.009

X. Xiao et al., Analysis and Modelling of Power-Dependent Harmonic Characteristics of Modern PE Devices in LV Networks, IEEE Trans. Power Deliv., vol. 32, no. 2, pp. 1014-1023, Apr. 2017.
https://doi.org/10.1109/TPWRD.2016.2574566

R. Langella, A. Testa, J. Meyer, F. Moller, R. Stiegler, and S. Z. Djokic, Experimental-Based Evaluation of PV Inverter Harmonic and Interharmonic Distortion Due to Different Operating Conditions, IEEE Trans. Instrum. Meas., vol. 65, no. 10, pp. 2221-2233, 2016.
https://doi.org/10.1109/TIM.2016.2554378

R. R. A. Fortes, R. F. Buzo, and L. C. O. de Oliveira, Harmonic distortion assessment in power distribution networks considering DC component injection from PV inverters, Electr. Power Syst. Res., vol. 188, no. June, p. 106521, 2020.
https://doi.org/10.1016/j.epsr.2020.106521

H. Dghim, A. El-Naggar, and I. Erlich, Harmonic distortion in low voltage grid with grid-connected photovoltaic, Proc. Int. Conf. Harmon. Qual. Power, ICHQP, vol. 2018-May, pp. 1-6, 2018.
https://doi.org/10.1109/ICHQP.2018.8378851

S. Djokic, J. Meyer, F. Möller, R. Langella, and A. Testa, Impact of operating conditions on harmonic and interharmonic emission of PV inverters, 2015.
https://doi.org/10.1109/AMPS.2015.7312729

X. Xu et al., Aggregate harmonic fingerprint models of PV inverters. part 1: Operation at different powers, Proc. Int. Conf. Harmon. Qual. Power, ICHQP, vol. 2018-May, pp. 1-6, 2018.
https://doi.org/10.1109/ICHQP.2018.8378824

Q. Shi, H. Hu, W. Xu, and J. Yong, Low-order harmonic characteristics of photovoltaic inverters, Int. Trans. Electr. Energy Syst., vol. 26, no. 2, pp. 347-364, 2016.
https://doi.org/10.1002/etep.2085

E. Kaufhold, J. Meyer, and P. Schegner, Modular white-box model of single-phase photovoltaic systems for harmonic studies, 2019 IEEE Milan PowerTech, PowerTech 2019, pp. 1-6, 2019.
https://doi.org/10.1109/PTC.2019.8810426

X. Ge and Y. Liu, A Dynamic Parameter Model of Harmonic Source Networks, IEEE Trans. Power Deliv., vol. 35, no. 3, pp. 1093-1101, 2020.
https://doi.org/10.1109/TPWRD.2019.2932433

A. Lesage-Landry, S. Chen, and J. A. Taylor, Estimating the frequency coupling matrix from network measurements, IEEE Trans. Control Netw. Syst., vol. 7, no. 2, pp. 724-733, 2020.
https://doi.org/10.1109/TCNS.2019.2940265

Z. Guo et al., Aggregate Harmonic Load Models of Residential Customers. Part 2: Frequency-Domain Models, Proc. 2019 IEEE PES Innov. Smart Grid Technol. Eur. ISGT-Europe 2019, pp. 1-5, 2019.
https://doi.org/10.1109/ISGTEurope.2019.8905746

A. Bosovic et al., Deterministic aggregated harmonic source models for harmonic analysis of large medium voltage distribution networks, IET Gener. Transm. Distrib., vol. 13, no. 19, pp. 4421-4430, 2019.
https://doi.org/10.1049/iet-gtd.2018.7120

E. Tavukcu, S. Müller, and J. Meyer, Assessment of the performance of frequency domain models based on different reference points for linearization, Renew. Energy Power Qual. J., vol. 17, no. 17, pp. 435-440, 2019.
https://doi.org/10.24084/repqj17.337

A. Martínez-Peñaloza, L. Carrillo-Sandoval, G. Malagón-Carvajal, C. Duarte-Gualdrón, and G. Osma-Pinto, Determination of parameters and performance analysis of load models for fluorescent recessed lightings before power supply signal Determinación de parámetros y análisis de desempeño de modelos de carga para fluorescent recessed lightings ante variaciones, DYNA, vol. 87, no. 215, pp. 163-173, 2020.
https://doi.org/10.15446/dyna.v87n215.85239

J. Yong, L. Chen, A. B. Nassif, and W. Xu, A Frequency-Domain Harmonic Model for Compact Fluorescent Lamps, IEEE Trans. Power Deliv., vol. 25, no. 2, pp. 1182-1189, Apr. 2010.
https://doi.org/10.1109/TPWRD.2009.2032915

F. Wang, J. L. Duarte, M. A. M. Hendrix, and P. F. Ribeiro, Modeling and analysis of grid harmonic distortion impact of aggregated DG inverters, IEEE Trans. Power Electron., vol. 26, no. 3, pp. 786-797, 2011.
https://doi.org/10.1109/TPEL.2010.2091286

F. Wang, X. Feng, L. Zhang, Y. Du, and J. Su, Impedance-based analysis of grid harmonic interactions between aggregated flyback micro-inverters and the grid, IET Power Electron., vol. 11, no. 3, 2018.
https://doi.org/10.1049/iet-pel.2017.0356

S. Muller et al., Aggregate harmonic fingerprint models of PV inverters. Part 2: Operation of parallel-connected units, Proc. Int. Conf. Harmon. Qual. Power, ICHQP, vol. 2018-May, no. Lv, pp. 1-6, 2018.
https://doi.org/10.1109/ICHQP.2018.8378835

G. Osma-Pinto and G. Ordóñez-Plata, Measuring factors influencing performance of rooftop PV panels in warm tropical climates, Sol. Energy, vol. 185, no. January, pp. 112-123, 2019.
https://doi.org/10.1016/j.solener.2019.04.053

G. Osma-Pinto and G. Ordóñez-Plata, Measuring the effect of forced irrigation on the front surface of PV panels for warm tropical conditions, Energy Reports, vol. 5, pp. 501-514, 2019.
https://doi.org/10.1016/j.egyr.2019.04.010

G. Osma-Pinto and G. Ordóñez-Plata, Dynamic thermal modelling for the prediction of the operating temperature of a PV panel with an integrated cooling system, Renew. Energy, vol. 152, pp. 1041-1054, 2020.
https://doi.org/10.1016/j.renene.2020.01.132

G. Osma-Pinto, M. García-Rodríguez, J. Moreno-Vargas, and C. Duarte-Gualdrón, Impact evaluation of grid-connected PV systems on PQ parameters by comparative analysis based on inferential statistics, Energies, vol. 13, no. 7, pp. 1-19, 2020.
https://doi.org/10.3390/en13071668

M. Garcia-Rodriguez, J. Moreno-Vargas, G. Osma-Pinto, and C. Duarte-Gualdron, Study of the impact of grid connected PV system on PQ through a comparative analysis by scenarios, in 2019 IEEE Workshop on Power Electronics and Power Quality Applications, PEPQA, 2019, pp. 1-6.
https://doi.org/10.1109/PEPQA.2019.8851557

A. B. Nassif, J. Yong, and W. Xu, Measurement-based approach for constructing harmonic models of electronic home appliances, IET Gener. Transm. Distrib., vol. 4, no. 3, p. 363, 2010.
https://doi.org/10.1049/iet-gtd.2009.0240

G. González Sua, G. Ordóñez, J. Barrero Perez, C. Duarte Gualdrón, and J. Bautista, Measurement of the magnitudes of power and electrical energy under the new conditions of electrical systems, Rev. UIS Ing., vol. 8, no. 1, pp. 9-19, 2009.

A. Varatharajan, S. Schoettke, J. Meyer, and A. Abart, Harmonic emission of large PV installations case study of a 1 MW solar campus, Renew. Energy Power Qual. J., vol. 1, no. 12, pp. 701-706, 2014.
https://doi.org/10.24084/repqj12.460

X. Xu et al., Harmonic emission of PV inverters under different voltage supply conditions and operating powers, in Proceedings of International Conference on Harmonics and Quality of Power, ICHQP, 2016, vol. 2016-Decem.
https://doi.org/10.1109/ICHQP.2016.7783394


Refbacks

  • There are currently no refbacks.



Please send any question about this web site to info@praiseworthyprize.com
Copyright © 2005-2024 Praise Worthy Prize