Harmonic analysis currently plays an important role for the power quality analysis because the non-linear loads, as source of the harmonic distortion, have significantly increased. The harmonic distortion influences power quality in power systems such as overheating of electrical equipment and aging of electrical equipment. Therefore, non-linear loads should be monitored in real time. This research proposes the design and implementation of the prototype current harmonic analysis that can be applied in real time based on S-transform Method. The equipment of this prototype can be explained as follows: CT-235, TZ2L9 and CT for KWH meters as current sensor, microcontroller AT mega 8535 as data acquisition, and Visual Basic software as displaying current waveform, current spectrum, rms current value, and total harmonic distortion (THD) for current. S-transform method is used to obtain the THD for current. The experimental result is validated by FLUKE 43B and the THD for current is accurately measured.
Copyright © 2016 Praise Worthy Prize - All rights reserved.

Keywords


Real-Time Monitoring; Microcontroller; S-Transform; THD

Full Text:

PDF


References


T. Yang, H. Pen, D. Wang, Z. Wang, Harmonic Analysis in Integrated Energy System Based on Compressed Sensing, Applied Energy, vol. 165, March 2016, pp. 583-591.
http://dx.doi.org/10.1016/j.apenergy.2015.12.058

Parithimar Kalaignan, T., Senthilkumar, J., Suresh, Y., A novel dissociated current control technique for harmonic minimization in non-linear loads, (2014) International Review on Modelling and Simulations (IREMOS), 7 (1), pp. 125-131.

Jayachandran, J., Sachithanandam, R.M., Artificial intelligence based controller for series and shunt active filters for power quality improvement, (2015) International Review of Automatic Control (IREACO), 8 (3), pp. 180-190.
http://dx.doi.org/10.15866/ireaco.v8i3.5942

Sridevi, T., Ramesh Reddy, K., Harmonic mitigation and comparison in a 15-bus network with combined hybrid active filter using SRF and pq-algorithms, (2014) International Review of Automatic Control (IREACO), 7 (2), pp. 233-239.

Arrillaga, J., Watson, N.R., “Power System Harmonics Second Edition”, John Wiley & Sons Ltd, England, Ch. 1, 2, 5, 2003

D. Srinivasan, W. S. Ng, and A. C. Liew, “Neural network-based signature recognition for harmonic source identification,” IEEE Trans. Power Del., vol. 21, no. 01, pp. 398–405, January 2006.
http://dx.doi.org/10.1109/tpwrd.2005.852370

C. F. Nascimento, A. A. Oliveira Jr., A. Goedtel., A. B. Dietrich., “Harmonic distortion monitoring for nonlinear loads using neural- network-method”, Applied Soft Computing 13 (2013) 475–482
http://dx.doi.org/10.1016/j.asoc.2012.08.043

IEEE Standard 519-1992, “Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems”, Institute of Electrical and Electronics Engineers, June 1992
http://dx.doi.org/10.1109/ieeestd.1993.114370

F. Zhang, Z. Geng, W. Yuan, “The Algorithm of interpolating Windowed FFT for harmonic Analysis of electric Power System”, IEEE Trans. Power Del., Vol. 16, No. 2, Apr. 2001
http://dx.doi.org/10.1109/61.915476

H.Qian, R. Zhao, T. Chen, “Interhamonics Analysis Based on Interpolating Windowed FFT Algorithm” IEEE Trans. Power Del, Vol. 22, no. 2, Apr. 2007
http://dx.doi.org/10.1109/tpwrd.2007.893187

Granados-Lieberman, D., Romero-Tronsoso, R.J., Osomio-Rios, R.A., Garcia-Perez, A., Cabal-Yepez, E., “Techniques and Methodologies for Power Quality Analysis and Disturbances Classification in Power Systems: a review”, IET Generation, Transmission and Distribution, 2010
http://dx.doi.org/10.1049/iet-gtd.2010.0466

Nath, S., P. Sinha, S. K. Goswami,”A Wavelet based Novel Method for the detection of harmonic sources in power systems”, Electrical Power and Energy Systems 40 (2012) 54–61
http://dx.doi.org/10.1016/j.ijepes.2012.02.005

M. A. S. Masoum. S. Jamali, N. Ghaffarzadeh, “Detection and Classification of Power Quality Disturbances Using Discrete Wavelet Transform and Wavelet Networks”, IET Sci. Meas. Technol. vol. 4, Iss. 4, pp. 193-205, 2010
http://dx.doi.org/10.1049/iet-smt.2009.0006

O. Poisson, P. Rioual, M. Meunier, “Detection and Measurement of Power Quality Disturbances Using Wavelet Transform”, IEEE Trans. Power Del. vol. 15, no. 3, Jul. 2000
http://dx.doi.org/10.1109/61.871372

S. Santoso, E. J. Powers, W. M. Grady, A.C. Parsons, “Power Quality Disturbances Waveform Recognition Using Wavelet Based Naural Classifier-Part 1: Theoretical Foundation”, IEEE Trans. Power Del. vol. 15, no. 1, Jan. 2000
http://dx.doi.org/10.1109/61.847255

Ghaemi, A. H, Abyaneh HA, Mazlumi K. “Harmonic indices assessment by wavelet transform” Electr Power Energy Syst 2011; 33: 1399–409.
http://dx.doi.org/10.1016/j.ijepes.2011.06.020

C.H. Lin, C.H. Wang, “Adaptive Wavelet Networks for Power-Quality Detection and Discrimination in a Power System”, IEEE Trans. Power Del. vol. 21, no. 3, Jul. 2006
http://dx.doi.org/10.1109/tpwrd.2006.874105

Stockwell, R.G., “Why Use S-Transform”, Northwest Research Associates, Colorado Research Associates Division, 3380 Mitchell Lane, Boulder Colorado USA 80301


Refbacks

  • There are currently no refbacks.



Please send any question about this web site to info@praiseworthyprize.com
Copyright © 2005-2024 Praise Worthy Prize