Experimental Evaluation of Time Harmonic Detection Methods for Shunt Active Power Filter


(*) Corresponding author


Authors' affiliations


DOI's assignment:
the author of the article can submit here a request for assignment of a DOI number to this resource!
Cost of the service: euros 10,00 (for a DOI)

Abstract


The active power filters, APFs, can be used as a practical solution to solve the problems caused by the lack of electric power quality. One of the most discussed software part (in the case of DSP implementation) of an active filter is the harmonic detection method.  In this paper, a comparison study of three harmonic detection methods for a shunt active power filter that are synchronous reference frame method, notch filter detection method, and PQ method. The compensation characteristics of each algorithm with the respective control scheme are proved experimentally and we examine the impacts of active filter parameters in reducing harmonics distortion are study
Copyright © 2013 Praise Worthy Prize - All rights reserved.

Keywords


Shunt Active Power Filter; Harmonics; Time Domain; SFR Method; PQ Method; Notch Method

Full Text:

PDF


References


H. Akagi, Modern active filters and traditional passive filters, Bulletin of the Polish Academy of Sciences, Technical Sciences, 2006, Vol. 54, No. 3, 255-269.

Otcenasova, A., Altus, J., Bracinik, P., Power quality in practice, analysis of power quality and available solutions, (2012) International Review on Modelling and Simulations (IREMOS), 5 (4), pp. 1672-1678.

Senthilnathan, N., Manigandan, T., Artificial Neural Network based three phase shunt active filter for line harmonic elimination, (2011) International Review on Modelling and Simulations (IREMOS), 4 (6), pp. 2936-2943.

Chauhan, S.K., Shah, M.C., Tekwani, P.N., Investigations on current error space phasor based self adaptive hysteresis controller employed for Shunt Active Power Filter with different techniques of reference compensating current generation, (2012) International Review on Modelling and Simulations (IREMOS), 5 (2), pp. 803-817.

Narongrit, T., Areerak, K.-L., Areerak, K.-N., Optimal design of shunt active power filters using a particle swarm optimization, (2011) International Review on Modelling and Simulations (IREMOS), 4 (6), pp. 2871-2878.

Akagi, H., "Control strategy and site selection of a shunt active filter for damping of harmonic propagation in power distribution systems," Power Delivery, IEEE Transactions on , vol.12, no.1, pp.354,363, Jan 1997.

M. Aredes, L. F. C. Monteiro, A control strategy for shunt active filter, 10th International Conference on Harmonics and Quality of Power, 2002, 472 – 477.

Fang Zheng Peng, Application issues of active power filters, IEEE Industry Ap Magazine, 1998, Vol.4, 21 – 30.

H. Tedjini, Differentes strategies de la commande d'un convertisseur dc-ac triphase pour des applications aux systemes electriques, Ph.D. dissertation, University of Sciences and Technologies Oran USTO, Algeria, 2012.

Patricio Salmerón and Jesús R. Vázquez, Active power-line conditioners, In Antonio Moreno-Muñoz (Ed), Power Quality: Mitigation Technologies in a Distributed Environment, (Springer-Verlag London 2007, 232-287).

C.L. Chen, C.E. Lin, and C.L. Huang, An active filter for unbalanced three-phase system using synchronous detection method, IEEE Conference on Power Electronics Specialists (PESC '94), 1994, 1451-1455.

Saidi, S., Chebbi, S., Jouini, H., Harmonic and reactive power compensations by shunt active filter controlled by adaptive fuzzy logic, (2011) International Review on Modelling and Simulations (IREMOS), 4 (4), pp. 1487-1492.

E. Watanabe, H. Akagi, M. Aredes, The p-q theory for active filter control: some problems and solutions, Revista Controle & Automação, Vol.15 No.1, 2004.

S. Bhattacharya, T. M. Frank, and D. M. Divan, B. Banerjee, Active filter implementation, IEEE Industry Applications Magazine, Vol. 4, 1998, , 47 – 63.

M. Aredes, L. F. C. Monteiro, A control strategy for shunt active filter, 10th International Conference on Harmonics and Quality of Power, 2002, 472 – 477.

P. Jintakosonwit, H. Fujita, and H. Akagi, Control and Performance of a Fully Digital Controlled Shunt Active Filter for Installation on a Power Distribution System, IEEE Trans. Power Electronics, Vol. 17, No. 1, January 2002, 132-140.

François Defaÿ, Commande Prédictive Directe d’un Convertisseur Multicellulaire Triphasé Pour Une Application de Filtrage Actif, Ph.D dissertation, University of Toulouse, 4 december 2008.