An Up-to-Date Review of Low-Voltage Ride-Through Techniques for Doubly-Fed Induction Generator-Based Wind Turbines


(*) Corresponding author


Authors' affiliations


DOI's assignment:
the author of the article can submit here a request for assignment of a DOI number to this resource!
Cost of the service: euros 10,00 (for a DOI)

Abstract


This paper deals with low-voltage ride-through capability of wind turbines driven by a doubly-fed induction generator. This is one of the biggest challenges facing massive deployment of wind farms. With increasing penetration of wind turbines in the grid, grid connection codes in most countries require that they should remain connected to maintain reliability during and after a short-term fault. This results in low-voltage ride-through with only 15% remaining voltage at the point of common coupling, possibly even less. In addition, it is required for wind turbines to contribute to system stability during and after fault clearance. To fulfill the low-voltage ride-through requirement for doubly-fed induction generator-based wind turbines, there are two problems to be addressed, namely, rotor inrush current that may exceed the converter limit and the DC-link overvoltage. Further, it is required to limit the doubly-fed induction generator transient response oscillations during the voltage sag to increase the gear lifetime and generator reliability. There is a rich literature addressing countermeasures for LVRT capability enhancement in DFIGs; this paper is therefore intended as an up-to-date review of solutions to the low-voltage ride-through issue. Moreover, attempts are also made to highlight future issues so as to index some emerging solutions
Copyright © 2015 Praise Worthy Prize - All rights reserved.

Keywords


Wind Turbine; Doubly-Fed Induction Generator; Low Voltage Ride-Through; Grid Requirements

Full Text:

PDF


References


R. Passey, T. Spooner, I. MacGill, M. Watt and K. Syngellakis, “The potential impacts of grid-connected distributed generation and how to address them: A review of technical and non-technical factors,” Energy Policy, vol. 39, n°10, pp. 6280-6290, October 2011.
http://dx.doi.org/10.1016/j.enpol.2011.07.027

FERC, “Interconnection for wind energy,” Docket N°RM05-4-000 – Order N°661, USA, June 2005.

FERC, “Interconnection for wind energy,” Docket N°RM05-4-001; Order N°661-A, USA, December 2005.

E.On Netz GmbH, Bayreuth, Grid Code, High- and Extra-High Voltage, April 2006, available at http://www.eon-netz.com/.

Ireland National Grid, Grid Code Version 2, “Wind farm power station grid code provisions, WFPS1,” pp.213-216, January 2007.

X. Yingcheng and T. Nengling, “Review of contribution to frequency control through variable speed wind turbine,” Renewable Energy, vol. 36, n°6, pp 1671-1677, June 2011.
http://dx.doi.org/10.1016/j.renene.2010.11.009

M. Liserre, R. Cardenas, M. Molinas and J. Rodriguez, “Overview of multi-MW wind turbines and wind parks,” IEEE Trans. Industrial Electronics, vol. 58, n°4, pp. 1081-1095, April 2011.
http://dx.doi.org/10.1109/tie.2010.2103910

Mohsen Rahimi, “Dynamic performance assessment of DFIG-based wind turbines: A review, Renewable and Sustainable Energy Reviews,” vol. 37, pp. 852-866, September 2014.
http://dx.doi.org/10.1016/j.rser.2014.05.072

C. Sasi and G. Mohan, “Power quality improvement of grid connected wind energy conversion system during transient fault,” International Journal on Energy Conversion, vol. 1, n°1, pp. 28-34, January 2013.
http://dx.doi.org/10.5120/12176-8166

Y. Amirat, M.E.H. Benbouzid, B. Bensaker and R. Wamkeue, “Generators for wind energy conversion systems: State of the art and coming attractions,” Journal of Electrical Systems, vol. 3, n°1, pp. 26-38, March 2007.
http://dx.doi.org/10.1109/iemdc.2007.383639

S. Tohidi, P. Tavner, R. McMahon, H. Oraee, M.R. Zolghadri, S. Shao and E. Abdi, “Low voltage ride-through of DFIG and brushless DFIG: Similarities and differences,” Electric Power Systems Research, vol. 110, pp. 64-72, May 2014.
http://dx.doi.org/10.1016/j.epsr.2013.12.018

H.T. Jadhav and R. Roy, “A comprehensive review on the grid integration of doubly fed induction generator,” International Journal of Electrical Power & Energy Systems, vol. 49, pp. 8-18, July 2013.
http://dx.doi.org/10.1016/j.ijepes.2012.11.020

E. Gómez-Lázaro, J.A. Fuentes, A. Molina-García and M. Cañas-Carretón, “Characterization and visualization of voltage dips in wind power installations,” IEEE Trans. Power Delivery, vol. 24, n°4, pp. 2071-2078, October 2009.
http://dx.doi.org/10.1109/tpwrd.2009.2027513

M. Ezzat, M.E.H. Benbouzid, S.M. Muyeen and L. Harnefors, “Low-voltage ride-through techniques for DFIG-based wind turbines: State-of-the-art review and future trends,” in Proceedings of the 2013 IEEE IECON, Vienna (Austria), pp. 7681-7686, November 2013.
http://dx.doi.org/10.1109/iecon.2013.6700413

M. Tsili and S. Papathanassiou, “A review of grid code technical requirements for wind farms,” IET Renewable Power Generation, vol. 3, n°3, pp. 308-332, September 2009.
http://dx.doi.org/10.1049/iet-rpg.2008.0070

B. Singh and S.N. Singh, “Wind power interconnection into the power system: A review of grid code requirements,” The Electricity Journal, vol. 22, n°5, pp. 54-63, 2009.
http://dx.doi.org/10.1016/j.tej.2009.04.008

B. Singh, S.N. Singh and L. Wang, Electric grid connection and system operational aspect of wind power generation, in Wind Energy Conversion System: Technology and Trends, S.M. Muyeen, (Eds.), Springer-Verlag: UK 2012.
http://dx.doi.org/10.1007/978-1-4471-2201-2_12

M. Mohseni and S.M. Islam, “Review of international grid codes for wind power integration: Diversity, technology and a case for global standard,” Renewable and Sustainable Energy Reviews, vol.16, n°6, pp. 3876-3890, August 2012.
http://dx.doi.org/10.1016/j.rser.2012.03.039

M. Mohseni and S.M. Islam, “Transient control of DFIG-Based wind power plants in compliance with the Australian grid code,” IEEE Trans. Power Electronics, vol. 27, n°2, pp. 2813-2824, June 2012.
http://dx.doi.org/10.1109/tpel.2011.2174380

F. Iov, A. D. Hansen, P. Sørensen and N. A. Cutululis, “Mapping of grid faults and grid codes,” Tech. Rep. Risø-R-1617(EN), Risø Nat. Lab., Tech. Univ. Denmark, Roskilde, Denmark, Jul. 2007.

G.D. Marques and D.M. Sousa, “Understanding the doubly fed induction generator during voltage dips,” IEEE. Trans. Energy Conversion, vol. 27, n°2, pp. 421-431, June 2012.
http://dx.doi.org/10.1109/tec.2012.2189214

Y. Ling and X. Cai, “Rotor current dynamics of doubly fed induction generators during grid voltage dip and rise,” International Journal of Electrical Power & Energy Systems, vol. 44, n°1, pp. 17-24, January 2013.
http://dx.doi.org/10.1016/j.ijepes.2012.07.032

F.K.A. Lima, A. Luna, P. Rodriguez, E.H. Watanabe and F. Blaabjerg, “Rotor voltage dynamics in the doubly fed induction generator during grid faults,” IEEE Trans. Power Electronics, vol. 25, n°1, pp. 118-13, January 2010.
http://dx.doi.org/10.1109/tpel.2009.2025651

P. da Costa, H. Pinheiro, T. Degner and G. Arnold, “Robust controller for DFIGs of grid-connected wind turbines,” IEEE Trans. Industrial Electronics, vol. 58, n°9, pp. 4023-4038, September 2011.
http://dx.doi.org/10.1109/tie.2010.2098630

M.J. Hossain, H.R. Pota, V.A. Ugrinovskii and R.A. Ramos, “Simultaneous STATCOM and pitch angle control for improved LVRT capability of fixed-speed wind turbines,” IEEE. Trans. Sustainable Energy, vol. 1, n°3, pp. 142-151, October 2010.
http://dx.doi.org/10.1109/tste.2010.2054118

M.J. Hossain, H.R. Pota and R.A. Ramos, “Robust STATCOM control for the stabilisation of fixed-speed wind turbines during low voltages,” Renewable Energy, vol. 36, n°11, pp. 2897-2905, November 2011.
http://dx.doi.org/10.1016/j.renene.2011.04.010

K.E. Okedu, S.M. Muyeen, R. Takahashi and J. Tamura, “Wind farms fault ride through using DFIG with new protection scheme,” IEEE Trans. Sustainable Energy, vol. 3, n°3, pp. 242-254, April 2012.
http://dx.doi.org/10.1109/tste.2011.2175756

M. Rahimi and M. Parniani, “Efficient control scheme of wind turbines with doubly fed induction generators for low-voltage ride-through capability enhancement,” IET Renewable Power Generation, vol. 4, n°3, pp. 242-252, 2010.
http://dx.doi.org/10.1049/iet-rpg.2009.0072

M. Rahimi and M. Parniani, “Low voltage ride-through capability improvement of DFIG-based wind turbines under unbalanced voltage dips,” International Journal of Electrical Power & Energy Systems, vol. 60, pp. 82-95, September 2014.
http://dx.doi.org/10.1016/j.ijepes.2014.02.035

S.M. Muyeen, R. Takahashi, T. Murata, J. Tamura, M.H. Ali, Y. Matsumura, A. Kuwayama and T. Matsumoto, “Low voltage ride through capability enhancement of wind turbine generator system during network disturbance,” IET Renewable Power Generation, vol. 3, n°1, pp. 65-74, 2009.
http://dx.doi.org/10.1049/iet-rpg:20070116

S.M. Muyeen, R. Takahashi, M.H. Ali, T. Murata and J. Tamura, “Transient stability augmentation of power system including wind farms by using ECS,” IEEE Trans. Power Systems, vol. 23, n°3, pp. 1179-1187, August 2008.
http://dx.doi.org/10.1109/tpwrs.2008.920082

F. Díaz-González, A. Sumper, O. Gomis-Bellmunt and R. Villafáfila-Robles, “A review of energy storage technologies for wind power applications,” Renewable and Sustainable Energy Reviews, vol. 16, n°4, pp. 2154-2171, May 2012.
http://dx.doi.org/10.1016/j.rser.2012.01.029

A.H.M.A. Rahim and E.P. Nowicki, “Supercapacitor energy storage system for fault ride-through of a DFIG wind generation system,” Energy Conversion and Management, vol. 59, pp. 96-102, July 2012.
http://dx.doi.org/10.1016/j.enconman.2012.03.003

M.J. Hossain, H.R. Pota, V.A. Ugrinovskii and R.A. Ramos, “Improved low-voltage-ride-through capability of fixed speed wind turbines using decentralised control of STATCOM with energy storage system,” IET Generation, Transmission & Distribution, vol. 6, n°8, pp. 719-730, 2012.
http://dx.doi.org/10.1049/iet-gtd.2011.0537

S.I. Gkavanoudis and C.S. Demoulias, “A combined fault ride-through and power smoothing control method for full-converter wind turbines employing supercapacitor energy storage system,” Electric Power Systems Research, vol. 106, pp. 62-72, January 2014.
http://dx.doi.org/10.1016/j.epsr.2013.08.007

W. Guo, L. Xiao and S. Dai, “Enhancing low-voltage ride-through capability and smoothing output power of DFIG with a superconducting fault-current limiter–magnetic energy storage system,” IEEE Trans. Energy Conversion, vol. 27, n°2, pp. 277-295, June 2012.
http://dx.doi.org/10.1109/tec.2012.2187654

J. Liang; W. Qiao and R.G. Harley, “Feed-forward transient current control for low-voltage ride-through enhancement of DFIG wind turbines,” IEEE. Trans. Energy Conversion, vol. 25, n°3, pp. 836-843, September 2010.
http://dx.doi.org/10.1109/tec.2010.2048033

D. Ramirez, S. Martinez, F. Blazquez and C. Carrero, “Use of STATCOM in wind farms with fixed-speed generators for grid code compliance,” Renewable Energy, vol. 37, n°1, pp. 202-212, January 2012.
http://dx.doi.org/10.1016/j.renene.2011.06.018

P.S. Flannery and G. Venkataramanan, “A fault tolerant doubly fed induction generator wind turbine using a parallel grid side rectifier and series grid side converter,” IEEE Trans. Power Electronics, vol. 23, n°3, pp. 1126-1135, May 2008.
http://dx.doi.org/10.1109/tpel.2008.921179

L. Teng S. Shiyi P. Malliband, E. Abdi and R.A. McMahon, “Crowbarless fault ride-through of the brushless doubly fed induction generator in a wind turbine under symmetrical voltage dips,” IEEE Trans. Industrial Electronics, vol. 60, n°7, pp. 2833-2841, July 2013.
http://dx.doi.org/10.1109/tie.2012.2208437

L. Yang, Z. Xu, J. Ostergaard, Z.Y. Dong and K.P. Wong, “Advanced control strategy of DFIG wind turbines for power system fault ride through,” IEEE. Trans. Power Systems, vol. 27, n°2, pp. 713-722, May 2012.
http://dx.doi.org/10.1109/tpwrs.2011.2174387

A.E. Leon, J.M. Mauricio and J.A. Solsona, “Fault ride-through enhancement of DFIG-based wind generation considering unbalanced and distorted conditions,” IEEE. Trans. Energy Conversion, vol. 27, n°3, pp. 775-783, September 2012.
http://dx.doi.org/10.1109/tec.2012.2204756

R. Cardenas, R. Pena, S. Alepuz and G. Asher, “Overview of control systems for the operation of DFIGs in wind energy applications,” IEEE Trans. Industrial Electronics, vol. 60, n°7, pp. 2776-2798, July 2013.
http://dx.doi.org/10.1109/tie.2013.2243372

T. Long, S. Shao, C.Y. Li, Chun-Yin, E. Abdi and R.A. McMahon, “Crowbarless fault ride-through of the brushless doubly fed induction generator in a wind turbine under symmetrical voltage dips,” IEEE Trans. Industrial Electronics, vol. 60, n°7, pp. 2833-2841, July 2013.
http://dx.doi.org/10.1109/tie.2012.2208437

H. Geng, C. Liu and G. Yang, “LVRT capability of DFIG-based WECS under asymmetrical grid fault condition,” IEEE Trans. Industrial Electronics, vol. 60, n°6, pp. 2495-2509, June 2013.
http://dx.doi.org/10.1109/tie.2012.2226417

S. Xiao, G. Yang, H. Zhou and H. Geng, “An LVRT control strategy based on flux linkage tracking for DFIG-based WECS,” IEEE Trans. Industrial Electronics, vol. 60, n°7, pp. 2820-2832, July 2013.
http://dx.doi.org/10.1109/tie.2012.2205354

M.J. Hossain, H.R. Pota and R.A. Ramos, “Robust STATCOM control for the stabilisation of fixed-speed wind turbines during low voltages,” Renewable Energy, vol. 36, n°11, pp. 2897-2905, November 2011.
http://dx.doi.org/10.1016/j.renene.2011.04.010

T.D. Vrionis, X.I. Koutiva and N.A. Vovos, “A genetic algorithm-based low voltage ride-through control strategy for grid connected doubly fed induction wind generators,” IEEE Trans. Power Systems, vol. 29, n°3, pp. 1325-1334, May 2014.
http://dx.doi.org/10.1109/tpwrs.2013.2290622

M.J. Hossain, T.K. Saha, N. Mithulananthan and H.R. Pota, “Control strategies for augmenting LVRT capability of DFIGs in interconnected power systems,” IEEE Trans. Industrial Electronics, vol. 60, n°6, pp. 2510-2522, June 2013.
http://dx.doi.org/10.1109/tie.2012.2228141

K.H. Kim, Y.C. Jeung, D.C. Lee and H.G. Kim, “LVRT scheme of PMSG wind power systems based on feedback linearization,” IEEE. Trans. Power Electronics, vol. 27, n°5, pp. 2376-2384, May 2012.
http://dx.doi.org/10.1109/tpel.2011.2171999

A.H.M.A. Rahim and E.P. Nowicki, “Performance of a grid-connected wind generation system with a robust susceptance controller,” Electric Power Systems Research, vol.81, n°1, pp. 149-157, January 2011.
http://dx.doi.org/10.1016/j.epsr.2010.08.002

M.E.H. Benbouzid, B. Beltran, Y. Amirat, G. Yao, J. Han and H. Mangel, “Second-order sliding mode control for DFIG-based wind turbines fault ride-through capability enhancement,” ISA Transactions, vol. 53, n°3, pp. 827-833, May 2014.
http://dx.doi.org/10.1016/j.isatra.2014.01.006

Benbouzid, M., Beltran, B., Ezzat, M., Breton, S., DFIG driven wind turbine grid fault-tolerance using high-order sliding mode control, (2013) International Review on Modelling and Simulations (IREMOS), 6 (1), pp. 29-32.

B. Beltran, M.E.H. Benbouzid and T. Ahmed-Ali, “Second-order sliding mode control of a doubly fed induction generator driven wind turbine,” IEEE Trans. Energy Conversion, vol. 27, n°2, pp. 261-269, June 2012.
http://dx.doi.org/10.1109/tec.2011.2181515

D. Ramirez, S. Martinez, C. Carrero and C.A. Platero, “Improvements in the grid connection of renewable generators with full power converters,” Renewable Energy, vol. 43, pp. 90-100, July 2012.
http://dx.doi.org/10.1016/j.renene.2011.11.054

P. Crossley and A. Beviz, “Smart energy systems: Transitioning renewables onto the grid,” Renewable Energy Focus, vol. 11, n°5, pp. 58-59, September–October 2010.
http://dx.doi.org/10.1016/s1755-0084(10)70118-6

http://www.elspec-ltd.com/

http://www.amsc.com/

http://www.zigor.com/

J.M. Corcelles, J.L. Rodríguez-Amenedo, D. Santos and S. Arnaltes, “Voltage sag compensation for providing wind turbine low voltage ride-through capability,” in Proceedings of the 2009 EWEC, Marseille (France), pp.1-3, March 2009.


Refbacks

  • There are currently no refbacks.



Please send any question about this web site to info@praiseworthyprize.com