Open Access Open Access  Restricted Access Subscription or Fee Access

Open Switch Fault Detection and Fault Tolerant of Power Converter Fed DFIG in WECS


(*) Corresponding author


Authors' affiliations


DOI: https://doi.org/10.15866/ireaco.v10i3.11528

Abstract


This paper work addresses the detection of converter open switch faults and the fault tolerant of power converters fed Doubly Fed Induction Generator (DFIG) in Wind Energy Conversion Systems (WECS). The stator flux-oriented vector control algorithm is used to control active and reactive power supplied by the stator windings. The mean value of the rotor current diagnosis technique is adopted for fault detection. The fault tolerant topology used for service continuity is that with a redundant leg. The simulations are performed using the Matlab / Simulink environment and Sim power. The fault operation is analyzed and the detection method and fault-tolerant topology used are tested with encouraging results.
Copyright © 2017 Praise Worthy Prize - All rights reserved.

Keywords


DFIG; Wind Turbines; Open Switch; Detection; Fault Tolerant; Redundancy

Full Text:

PDF


References


Touati, A., Abouloifa, A., Abd Elmounim, E., Aboulfatah, M., Majdoul, R., Moutabir, A., Modeling and Control of a Three Phase DC-AC Converter Connected to the Network for a Wind Power System Equipped with a DFIG, (2014) International Review on Modelling and Simulations (IREMOS), 7 (2), pp. 231-237.

Boukhriss, A., Nasser, T., Essadki, A., Boualouch, A., Improved Control for DFIG used in Wind Energy Conversion Systems, (2014) International Review of Automatic Control (IREACO), 7 (4), pp. 403-411.

D. Partha Sarati, H. Kyeong-Hwa, Voltage-based On-Line Fault Detection and Faulty Switch Identification under Multiple Open-Switches in Grid-Connected Wind Power Converter, International Journal of Control and Automation, Vol. 7, No. 11 (2014), pp. 419-434.
http://dx.doi.org/10.14257/ijca.2014.7.11.39

H. Polinder, H. Lendenmann, R. Chin and W.M. Arshad, Fault Tolerant Generator Systems for Wind Turbines, Electric Machines and Drives Conference, 2009. IEMDC '09. IEEE International.
http://dx.doi.org/10.1109/iemdc.2009.5075278

F. Bensouda, A. Haddi, Arshad Introduction on Advances in Diagnosis for Power Electronics Devices in wind energy, based on a doubly-fed asynchronous generator, international Conference on Green Energy and Environmental Engineering (GEEE-2014) Tunisia - 2014.
http://dx.doi.org/10.1109/poweri.2014.7117631

B. Lu and S. K. Sharma, A literature review of IGBT fault diagnostic and protection methods for power inverters, Industry Applications, IEEE Transactions on, vol. 45, pp. 1770–1777, 2009.
http://dx.doi.org/10.1109/tia.2009.2027535

S. Mohamed, Z. Haitham and S. Ashraf, OPEN-CIRCUIT Fault Diagnosis Of Three-Phase Induction Motor Drive Systems, Journal of Electrical Engineering .
http://dx.doi.org/10.1109/icaccs.2016.7586403

Cherif, B., Bendiabdellah, A., Khelif, M., Detection of Open-Circuit Fault in a Three-Phase Voltage Inverter Fed Induction Motor, (2016) International Review of Automatic Control (IREACO), 9 (6), pp. 374-382.
http://dx.doi.org/10.15866/ireaco.v9i6.10268

B. Cherif, M. Bendjebbar, A. Bendiabdellah, Diagnostic of open-circuit fault in three phase voltage inverter fed induction motor, 4th International Conference on Electrical Engineering (ICEE), Boumerdes, Algeria2015.
http://dx.doi.org/10.1109/intee.2015.7416736

El Kachani, A., Chakir, E., Ait laachir, A., Jarou, T., Niaaniaa, A., Zerouaoui, J., Sedra, M., AC Grid Connected DFIG-Based Wind Turbine with Shunt Active Power Filter Based on Nonlinear Predictive Control, (2015) International Review on Modelling and Simulations (IREMOS), 8 (3), pp. 354-361.
http://dx.doi.org/10.15866/iremos.v8i3.6070

T. Riouch,., El-Bachtiri, R., Advanced Control Strategy of Doubly Fed Induction Generator Based Wind-Turbine during Symmetrical Grid Fault, (2014) International Review of Electrical Engineering (IREE), 9 (4), pp. 829-834.
http://dx.doi.org/10.15866/iree.v9i4.2306

A. Guediri, D. Ben Attous, Modeling and fuzzy control of a wind energy system based on double-fed asynchronous machine for supply of power to the electrical network, International Journal of System Assurance Engineering and Management, 18 June 2015.
http://dx.doi.org/10.1007/s13198-015-0367-1

A.Tamer, D. Toumi, A. Bendiabdellah , M.S. Boucherit, Inter-turn Stator and Rotor Fault in Doubly-Fed Induction Generator Based Wind Power System, Second International Conference On Electrical Engineering And Control Applications ICEECA’2014 Algeria - 2014.
http://dx.doi.org/10.1049/cp.2014.0914

A. Cordeiro, J. Palma, J. Maia, M. Resende, Detection and Diagnosis Solutions for Fault-Tolerant VSI, Journal of Power Electronics, Vol. 14, No. 6, pp. 1272-1280, November 2014.
http://dx.doi.org/10.6113/jpe.2014.14.6.1272

Ahmed, I., Zobaa, A Comparative Power Quality Study of Variable Speed Wind Turbines, (2016) International Journal on Energy Conversion (IRECON), 4 (4), pp. 97-104.
http://dx.doi.org/10.15866/irecon.v4i4.10828

Yang, S., Bryant, A., Mawby, P., Xiang, D., Ran, L., Tavner, P. An industry-based survey of reliability in power electronic converters, IEEE Trans. Ind. Appl., vol. 47, no. 3, 1441–1451, May. 2011.
http://dx.doi.org/10.1109/tia.2011.2124436

F. Yanhui, Z. Junwei, Q. Yingning, and F. Kai, “Fault tolerance for wind turbine power converter,” Renewable Power Generation Conference (RPG 2013), 2nd IET, 2013, pp. 1–4
http://dx.doi.org/10.1049/cp.2013.1831

A. Gaillard, S. Karimi, P. Poure, S. Saadate, and E. Gholipour,A fault tolerant converter topology for wind energy conversion system with doubly fed induction generator, in Power Electronics and Applications, European Journal of Electrical Engineering, 2007, pp. 1–6.
http://dx.doi.org/10.1109/epe.2007.4417601

A. Gaillard, P. Poure, and S. Saadate, FPGA-based reconfigurable control for switch fault tolerant operation of WECS with DFIG without redundancy, Renewable energy journal, vol. 55, pp. 35–48, 2013.
http://dx.doi.org/10.1016/j.renene.2012.11.027

Meo, S., Zohoori, A., Vahedi, A., Optimal design of permanent magnet flux switching generator for wind applications via artificial neural network and multi-objective particle swarm optimization hybrid approach, (2016) Energy Conversion and Management, 110, pp. 230-239.
http://dx.doi.org/10.1016/j.enconman.2015.11.062


Refbacks

  • There are currently no refbacks.



Please send any question about this web site to info@praiseworthyprize.com
Copyright © 2005-2024 Praise Worthy Prize