Experimental Study of Air Conditioning of the Building by Floor Cooling System


(*) Corresponding author


Authors' affiliations


DOI's assignment:
the author of the article can submit here a request for assignment of a DOI number to this resource!
Cost of the service: euros 10,00 (for a DOI)

Abstract


This study is focused on the air conditioning of the building by the floor cooling system. The floor cooling system works on the same principle as the heating floor principle, but the cooling floor absorbs calories instead of emitting them. However as the air conditioning of the building, the water running from the distribution network must be at a temperature lower than of the air room temperature.  Experimental work in the laboratory of air conditioning technology at the technical University of Applied Sciences THM (Giessen) was carried out. The supply chilled water temperature and the return chilled water temperature of the hydraulic module 2, the air room temperature and the floor surface temperature is achieved. Besides, the out flow of hydraulic module 2 as well as the evolution of the air speed in the experimental chamber is pointed out.


Copyright © 2014 Praise Worthy Prize - All rights reserved.

Keywords


Air conditioning, building, chilled water, cooling floor ,room

Full Text:

PDF


References


Ben hamed H. et al, . Convection mixte 3D. Application: Plancher Rafraichissement. 12éme journées internationales de thermique, Tanger (Maroc), Novembre 2005, pp. 255-258.

J.-H.Lim et al.,. Application of the control methods for radiant floor cooling system in residential building. Building and Environment vol.41, 2006 pp. 60-73.

Fraise J.,. La régulation thermique des bâtiments tertiaires : Application de la logique floue à la régulation centrale du chauffage en régime intermittent. Thèse de doctorat, Institut nationales des sciences appliquées de Lyon 1997.

J. Ren et al., .Very low temperature radiant heating/cooling indoor end system for efficient use of renewable energies” Solar Energy, vol.84 n.6, 2010,pp. 1072-1083.

D. Song et al., . Performance evaluation of a radiant floor cooling system integrated with dehumidified ventilation. Applied Thermal Engineering, vol.28 n.11-12, 2008, pp. 1299-1311.

Ali, C., Rabhi, K., Nciri, R., Nasri, F., Ben Bacha, H., New adsorption air conditioning system powered by solar energy; operation principals and winter mode modelling and simulation, (2013) International Review of Mechanical Engineering (IREME), 7 (1), pp. 96-104.

Ali, C., Nciri, R., Rabhi, K., Nasri, F., Ben Bacha, H., A study of an air-conditioning prototype powered by solar energy, (2013) International Review of Mechanical Engineering (IREME), 7 (1), pp. 60-66.

Sebai, R., Chouikh, R., Amara, K., Guizani, A., Numerical study of heat and mass transfer in a porous membrane used in energy recovery devices, (2011) International Review on Modelling and Simulations (IREMOS), 4 (4), pp. 1945-1951.


Refbacks

  • There are currently no refbacks.



Please send any question about this web site to info@praiseworthyprize.com
Copyright © 2005-2024 Praise Worthy Prize