A Low-Cost Device for Contactless Detection of Pacemaker Pulses


(*) Corresponding author


Authors' affiliations


DOI's assignment:
the author of the article can submit here a request for assignment of a DOI number to this resource!
Cost of the service: euros 10,00 (for a DOI)

Abstract


A new sensor capable to detect pacemaker pulses without using electrodes is presented. The magnetic field associated to the pacing current is sensed by a coil placed in proximity of the pacemaker wire, without the need of any electric connection with the patient. The new sensor is capable to provide accurate measurement of the occurrence and timing of pacemaker pulses. Hence, it provides important information about the pacemaker functioning, which can be used in patient’s monitoring  and pacemaker device assessment. An in-vitro testing of the new sensor was carried out involving a real unipolar pacemaker immersed in saline solution. A wideband ECG circuit was also realized to record pacemaker pulses. The electrocardiographic signal and the output of the sensor were simultaneously recorded and compared. A microcontroller-based circuit provides accurate timing measurements of inter-pulse intervals and pulse duration and display them in real-time. Preliminary results suggest the possibility to use the new sensor to achieve prolonged, passive, unobstructive and wearable monitoring of pacemaker patients during their daily life activities. Accurate timing of the pacemaker pulse can also support standard ECG diagnosis and measurement of the residual charge of the pacemaker battery.
Copyright © 2013 Praise Worthy Prize - All rights reserved.

Keywords


Pacemaker Pulse Detection; Inductive Sensor; Pacemaker Activation Timing; Wideband Electrocardiograph Device

Full Text:

PDF


References


H.G. Mond, A. Proclemer,. The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009--a World Society of Arrhythmia's project. Pacing Clin Electrophysiol., Vol. 34, n.8, August 2011, pp.1013-1027.

G. Gregoratos, M.D. Cheitlin, A. Conill, A.E. Epstein, C. Fellows, T.B. Ferguson Jr, R.A. Freedman, M.A. Hlatky, G.V. Naccarelli, S. Saksena, R.C. Schlant, M.J. Silka, ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Executive Summary--a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation). Circulation. 1998 Apr 7;97(13):1325-1335.

Ricke AD, Swiryn S, Bauernfeind RA, Conner JA, Young B, Rowlandson GI. Improved pacemaker pulse detection: clinical evaluation of a new high-bandwidth electrocardiographic system. J Electrocardiol. 2011 Mar-Apr;44(2):265-74.

Luo S, Johnston P, Macfarlane PW. Implanted cardiac pacemaker pulses as recorded from the body surface. J Electrocardiol. 2012 Nov-Dec;45(6):663-9.

Ricke AD, Swiryn S, Sahakian AV, Petrutiu S, Young B, Rowlandson GI. The relationship between programmed pacemaker pulse amplitude and the surface electrocardiogram recorded amplitude: application of a new high-bandwidth electrocardiogram system. J Electrocardiol. 2008 Nov-Dec;41(6):526-30.

Koenig J, Sahakian AV, Ricke A, Swiryn S. Observations of pacemaker pulses in high-bandwidth electrocardiograms and Dower-estimated vectorcardiograms. J Electrocardiol. 2011 Mar-Apr;44(2):275-81.

Mori N, Hara M, Miyake F, Sato C, Murayama M, Tamamura K, Kaneko M, Sirakawa O. Clinical assessment of a new method for pacing pulse detection using a hybrid circuit in digital Holter monitoring. Jpn Circ J. 2000 Aug;64(8):583-9.

Gargiulo G, Bifulco P, Cesarelli M, Ruffo M, Romano M, Calvo RA, Jin C, van Schaik A. An ultra-high input impedance ECG amplifier for long-term monitoring of athletes. Medical Devices (Auckl). 2010;3:1-9

Gargiulo G, Calvo RA, Bifulco P, Cesarelli M, Jin C, Mohamed A, van Schaik A. A new EEG recording system for passive dry electrodes. Clin Neurophysiol. 2010 May;121(5):686-93

Gargiulo GD, Shephard RW, Tapson J, McEwan A, Bifulco P, Cesarelli M, Jin C, Al-Ani A, Wang N, van Schaik A. Pregnancy detection and monitoring in cattle via combined foetus electrocardiogram and phonocardiogram signal processing. BMC Veterinary Research. September 2012; vol.8: n.164.

Gargiulo GD, Armin M, McEwan AL, Bifulco P, Cesarelli M, Jin C, Ruffo M, Tapson J, van Schaik A. Investigating the role of combined acoustic-visual feedback in one-dimensional synchronous brain computer interfaces, a preliminary study. Medical Devices: Evidence and Research. 2012;5(1):81–88 .

Gargiulo GD, McEwan AL, Bifulco P, Cesarelli M, Jin C, Tapson J, Thiagalingam A, Van Schaik A. Towards true unipolar bio-potential recording: A preliminary result for ECG. Physiological Measurement. January 2013; 34(1):N1-N7.

Design of Cardiac Pacemakers: J. G. Webster, ed., IEEE Press, 1995

Cerciello T, Bifulco P, Cesarelli M, Fratini A. A comparison of denoising methods for X-ray fluoroscopic images. Biomedical Signal Processing and Control. 2012 Nov; 7(6): 550-559 .

M. Cesarelli, P. Bifulco, T. Cerciello, M. Romano, L. Paura, X-ray fluoroscopy noise modeling for filter design, International Journal of Computer Assisted Radiology and Surgery, Vol. 8, n.2, March 2013, pp. 269-278

P. Bifulco, M. D'Apuzzo, A. Liccardo, M. Polisiero, Metrological issues concerning low cost EMG-controlled prosthetic hand. Proceedings of the Instrumentation and Measurement Technology Conference (I2MTC), 2012 IEEE International (13-16 May 2012), article number 6229550, pages: 1481 – 1486.

A. Baccigalupi, , D.L. Carnì, D. Grimaldi, A. Liccardo, Characterization of arbitrary waveform generator by low resolution and oversampling signal acquisition, Measurement: Journal of the International Measurement Confederation, Vol.45, n.10, October 2012, pp. 2498-2510.

M. D'Arco, A. Liccardo, N. Pasquino, ANOVA-based approach for DAC diagnostics, IEEE Transactions on Instrumentation and Measurement, vol.61, n.7, July 2012, pp. 1874-1882.

A. Baccigalupi, A. Liccardo, N. Pasquino, A methodology for testing immunity of field programmable analog arrays to radiated electromagnetic field, Measurement: Journal of the International Measurement Confederation, Vol.44, n.10, October 2011, pp. 2165-2174.

Fratini A, Cesarelli M, Bifulco P, Romano M. Relevance of motion artifact in electromyography recordings during vibration treatment. J Electromyogr Kinesiol. 2009 Aug;19(4):710-8.

Fratini A, La Gatta A, Bifulco P, Romano M, Cesarelli M. Muscle motion and EMG activity in vibration treatment. Med Eng Phys. 2009 Nov;31(9):1166-72.

Cesarelli, M., Fratini, A., Bifulco, P., La Gatta, A., Romano, M., Pasquariello, G. Analysis and modelling of muscles motion during whole body vibration. Eurasip Journal on Advances in Signal Processing 2010 , art. no. 972353.

Gargiulo G, Bifulco P, Cesarelli M, Jin C, McEwan A, van Schaik A. Wearable dry sensors with bluetooth connection for use in remote patient monitoring systems. Stud Health Technol Inform. 2010;161:57-65.

Gargiulo, G., Bifulco, P., Calvo, R.A., Cesarelli, M., Jin, C., Van Schaik, A. A mobile EEG system with dry electrodes. IEEE-BIOCAS Biomedical Circuits and Systems Conference, BIOCAS 2008 , 2008; art. no. 4696927 , pp. 273-276.

Gargiulo G, Bifulco P, McEwan A, Nasehi Tehrani J, Calvo RA, Romano M, Ruffo M, Shephard R, Cesarelli M, Jin C, Mohamed A, van Schaik A. Dry electrode bio-potential recordings. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Volume 2010, 2010, Pages 6493-6496

Bracale M, Monteagudo JL, Rossing N, Hakansson S, Reponen J, Bifulco P. Telemedicine in Europe--the TELEPLANS project. J Telemed Telecare. 2002; 8(5):308-10.

Bracale M, Cesarelli M, Bifulco P. Telemedicine services for two islands in the Bay of Naples. J Telemed Telecare. 2002; 8(1):5-10.


Refbacks

  • There are currently no refbacks.



Please send any question about this web site to info@praiseworthyprize.com
Copyright © 2005-2024 Praise Worthy Prize